Outlet tester
https://www.westfalia.uk/shop/wf-814865-socket-tester-72982 https://www.westfalia.uk/web/image/product.template/72982/image_1920?unique=a26e72d4 sold in the last 24 hours
About this item:
- This small tester can save lives
- Easy to use
- Displays 7 conditions
- Small & practical
| Item number | WF-814865 |
Verified Purchase
What does "Verified Purchase" mean?
Reviews marked as "Verified Purchase" come from customers who have actually purchased this product through our shop.
How do we verify this?
We automatically check whether the reviewer has a completed order containing this product. Only reviews from confirmed buyers receive the "Verified Purchase" badge.
Reviews without the "Verified Purchase" badge
Reviews that do not carry the "Verified Purchase" badge have not been verified for an actual purchase. We cannot guarantee that these reviewers have actually bought or used the product.
Reviews loaded: 15
Total attachments: 10
Images displayed: 10
Peter Hauer
Birgit Kiesslin
Constantin Zlat
Rafael Schmitz
Heinrich Stallj
Bodo Schulz
Michael Haut
Giuseppe Rizzi
Heiko Bähr
san car
Anke Freyer
Gottfried Nestl
Eckhard Loos
Kerstin Röthig
Archibald Grütz
Heike P.
16 AprKundendienst
ResponseThe socket tester is designed for testing according to VDE standards and is standard compliant according to VDE for the grounding test. This ensures reliable and safe use.
Anonym
07 AprKundendienst
ResponseYes, swapping phase and neutral is one of the 7 states that this tester reliably detects and displays. This is important for the correct function and safety of many electrical appliances.
Kunde
01 MarKundendienst
ResponseThe tester detects the 7 most common and potentially dangerous wiring errors such as missing earth or swapped wires. This also helps when checking older installations.
Silke K.
15 FebKundendienst
ResponseThe tester is designed for an operating temperature range of 0 to +40°C. As long as the temperature in your garage is within this range, use is possible.
Anja M.
27 JanKundendienst
ResponseYes, a mix-up of neutral conductor and grounding is a critical wiring error. The tester is able to display this as one of the 7 states.
Anonym
25 DecKundendienst
ResponseNo, quite the opposite. The socket tester is designed for easy handling, so even people without electrical expertise can quickly and safely test the sockets.
Jürgen H.
20 DecKundendienst
ResponseNo, the tester is designed to indicate the correct wiring of sockets using LEDs. It does not measure flowing currents or other electrical parameters.
Klaus M.
05 DecKundendienst
ResponseThe tester displays up to 7 different wiring conditions. This includes a number of typical errors that can affect safety.
Sandra B.
10 NovKundendienst
ResponseWith dimensions of 60x60x65 mm and a weight of only approx. 52 g, the tester is very compact and handy. It fits easily into any tool bag or a larger pocket.
Kunde
24 OctKundendienst
ResponseThe LED indicators of a socket tester usually signal standard wiring errors such as missing ground or swapped phase/neutral. When used with adapters in Swiss sockets, the indicators can be influenced by the adapters themselves or different wiring standards. For a precise interpretation of the light patterns, we recommend consulting the specific operating instructions of your tester.
Martina B.
06 OctKundendienst
ResponseThis means that the tester quickly detects dangerous errors in the socket wiring, such as missing grounding or incorrect polarity. This way, you can avoid potentially life-threatening situations.
Jörg B.
27 SepKundendienst
ResponseNo, the tester delivers results immediately, so you can test several sockets in a row without waiting. The simple handling makes it very efficient.
Anonym
26 SepKundendienst
ResponseThe tester recognizes 7 different wiring conditions, including swapped phase and neutral conductor or phase and protective conductor. A specific indication for only swapped neutral and protective conductor is not directly listed, but any deviation is signaled as an error.
Markus S.
09 SepKundendienst
ResponseYes, the operation is kept very simple: Plug in and read the LEDs. The 7 states are designed so that a quick and precise diagnosis is possible even without expert knowledge.
T.
20 AugKundendienst
ResponseYes, by reliably detecting 7 different and often dangerous wiring errors, the socket tester helps to avoid electrical accidents and thus protect lives.
Kundin
07 AugKundendienst
ResponseYes, the tester displays the status "L + PE (phase + protective conductor) swapped" via the LEDs. This way you can quickly identify this critical wiring error and have it corrected.
Julia R.
11 JulKundendienst
ResponseFor a long service life, store the device in a dry place at room temperature. If necessary, clean it only with a dry cloth.
Birgit S.
03 JunKundendienst
ResponseYes, the socket tester is designed for easy handling. The clear displays are easy to understand even for people without electrical expertise.
Martina P.
20 MayKundendienst
ResponseYes, the socket tester is specially designed for checking 230V safety contact sockets and extension cables. It is therefore ideal for everyday use in the household.
Stefan M.
16 MayKundendienst
ResponseThe socket tester detects 7 different wiring states and thus helps to identify electrical hazards. A separate FI test function, which triggers a circuit breaker, is not mentioned as a feature.
Kunde
04 MayKundendienst
ResponseAbsolutely. This practical tester is ideal for a quick and easy initial inspection of the existing sockets for correct basic function and safety.
Anonym
02 MayKundendienst
ResponseYes, the absence or a faulty connection of the protective conductor is one of the 7 wiring states that the tester can reliably display.
Markus Z.
05 AprKundendienst
ResponseThe tester delivers an immediate result as soon as it is plugged into the outlet. The display of the 7 states is immediate and directly readable.
Kunde
04 AprKundendienst
ResponseYes, this tester quickly and easily shows you whether the basic wiring of an outlet is correct and therefore safe. It can thus help to identify potential hazards.
Anonym
02 AprKundendienst
ResponseThanks to the simple operation and the clear display of the 7 states, the tester is easy to understand even for laymen. One look is enough to see the condition of the socket.
Kunde
29 MarKundendienst
ResponseYes, the tester explicitly indicates when the phase (L) is missing. This is one of the 7 error states that the device recognizes for safe diagnosis.
Peter H.
08 MarKundendienst
ResponseNo, the socket tester is specifically designed to check the correct wiring of safety contact sockets. A separate RCD test function is not integrated.
Kundin
07 MarKundendienst
ResponseYes, the tester is deliberately small and practical. It fits easily in any tool bag or drawer and is therefore always at hand.
Steffi W.
22 FebKundendienst
ResponseThe device is equipped with surge protection up to 300 V. This protects the tester in case of faulty wiring in the socket.
Kunde
12 FebKundendienst
ResponseThe socket tester is designed for an operating temperature of 0 to +40 °C. As long as the temperature is within this range, use in the basement is also possible.
Want to see more questions about this product?
Reviews (15)
Leave a Review
Birgit Kiesslin
Questions (36)
Ask Questions
Heike P.
16 AprKundendienst
ResponseThe socket tester is designed for testing according to VDE standards and is standard compliant according to VDE for the grounding test. This ensures reliable and safe use.
This small tester can save lives and prevent fires. No tool bag should be without it! With this small and handy device you can quickly check whether your 230V earthed sockets or extension leads are connected and wired correctly. The following 7 states are displayed via the built-in LEDs:
- OK
- PE (protective conductor) interrupted
- L (phase) missing
- N (neutral conductor) interrupted
- L + N (phase + neutral conductor) swapped
- L + PE (phase + protective conductor) swapped
- L + PE (phase + protective conductor) swapped & PE (protective conductor) interrupted.
Technical specifications:
- Nominal voltage: 230 V~ 50 Hz
- Overvoltage protection: 300 V
- Operating temperature: 0 to +40°C
Dimensions:
- 60 x 60 x 65 mm
| WWC Catalog 2025 | |
|---|---|